Magnesium Perchlorate (Anhydrone) | CAS 10034‑81‑8
Note: This product is intended for industrial applications only. Please adopt proper personal protective equipment during handling, storage and usage. Always refer to the corresponding SDS and comply with local safety, transportation and environmental regulations before operation. Keep away from food, feed, children and unauthorized personnel.
Magnesium Perchlorate (trade name Anhydrone) is white porous granular solid. It ranks among the most powerful inorganic chemical desiccants with extremely low equilibrium water‑vapour pressure. After absorbing water it will not turn sticky‑paste and internal pore channels remain uncollapsed, maintaining good gas‑column permeability. Its water‑absorbing capacity can reach a large percentage of self‑weight when converted into hexahydrate magnesium perchlorate.
基本信息
项目
Details
CAS Number
10034‑81‑8
分子式
Mg(ClO₄)₂
UN Number
UN 1475
危险类别
Class 5.1, PG II
HS编码
2829.90.0090
*CN‑10‑digit code for reference only. Import tariff code varies per destination country.
Filling desiccant for CHNS elemental analyser, trace‑moisture analyser and pyrolysis‑GC carrier‑gas drying tubes for deep gas‑stream purification.
Deep trace‑moisture removal for inert non‑reductive industrial gases: Ar, He, N₂, O₂.
Catalyst & dehydration agent for fine‑organic synthesis: acetal / ketal formation and electrophilic aromatic substitution reactions.
Selection & Application Advice
Porous granular grade (14‑30 mesh): For gas‑drying columns; low gas‑flow resistance, homogeneous water uptake.
Super‑fine powder grade: For heterogeneous drying & catalysis within liquid‑phase organic synthesis.
Key selection points: Low ignition‑loss value guarantees effective drying performance; high crush‑resistance prevents fine‑dust carry‑over into analytical detectors under continuous gas‑flow.
Solubility, Dosing & Safe Handling
Extremely soluble in water with strongly exothermic dissolution. ⚠️ Critical safety rule: Never use magnesium perchlorate to directly dry mixed organic solvents (alcohols, ether, THF). Explosive mixture risk. Only permitted for gas‑line dehydration and non‑reductive media.
Safety & Compliance
UN 1475, Class 5.1 Strong Oxidizer, PG II. GHS pictograms GHS03 + GHS07, signal word DANGER. Listed in global key hazardous‑chemical regulatory catalogues.
Typical TDS
项目
AR Premium Grade
Industrial Desiccant Grade
Test Method
外观
White porous particles (14‑30 mesh)
White porous powder / small granule
Visual & sieve analysis
Assay
≥99.3%
≥98.5%
EDTA Complexometric Titration
Water‑absorption capacity
≥33% of self‑weight
≥28%
Constant‑T humidity absorption test
Loss on drying @220℃
≤0.7%
≤1.2%
High‑temp gravimetry
Acidity (as HClO₄)
≤0.02%
≤0.05%
Acid‑base titration
Water‑insoluble matter
≤0.005%
≤0.01%
Gravimetric analysis
包装与储存
100 g / 500 g PTFE‑sealed thick‑wall moisture‑proof wide‑mouth bottles enclosed inside sealed tin cans; bulk 25 kg steel drums lined with aluminum‑foil barrier. Store in Class‑A hazardous‑chemical cool‑dry warehouse equipped with humidity‑monitoring facilities.
Thank you! Our compliance officer and sales team will verify your credentials and send official TDS/COA within 12 hours.Thank you! Our compliance officer and sales team will verify your credentials and send official TDS/COA within 12 hours.Thank you! Our compliance officer and sales team will verify your credentials and send official TDS/COA within 12 hours.